Error:
E1000 Failsafe
E1229 CPU2 VCORE
Replaced motherboard and CPU 2 from Dell support. System not showing error. Now stops and asks for F1 or F2(setup) to continue. Tech says we need to enter a service tag into BIOS using a DOS utility (attached):
-------- Original Message --------
Subject: RE: Case No. :3835346 - PE1950 / RHEL 4 EL Update 4 / Cluster / E1000 Failsafe E122C
Date: Tue, 22 Jan 2008 14:39:01 -0600
From:
To:
Here is the link to the exe file from support.dell.com
http://ftp.us.dell.com/utility/BR105717.exe
Manuals
http://support.dell.com/support/edocs/dta/XM590/00000015.htm#Asset%20Tag%20Utility
---truncated----
Next step is to make bootable DOS cdrom/floppy to run this utility and load it via a USB device. It is theoretically possible to PXE boot into a DOS image, but we have not tried it.
Resolution 2/1/2008 - Asked for Dell to dispatch onsite technician to expedite this. Tech discovered that issue was actually due to the CDROM controller being enabled and not finding a drive. He did also set the BIOS service tag.
--
BenMeekhof - 23 Jan 2008